# Normal distribution parameters for multi-family daily DHW demand variability.
# Used to compute fract_total_vol from load_shift_percent (percentile of days covered).
# Source: calibrated from multi-family occupancy stream data in original EcosizerEngine.
_LS_NORM_MEAN: float = 0.7052988591269841
_LS_NORM_STD: float = 0.08236427664525116
_LS_NORM_DIST: NormalDist = NormalDist(mu=_LS_NORM_MEAN, sigma=_LS_NORM_STD)
class StorageVolumeTooSmallError(ValueError):
"""
Raised when the sized storage volume is below the minimum required floor
(half the peak-hour demand at supply temperature).
"""
def __init__(self, storage_storageT_gal: float, minimum_gal: float, capacity_kbtuh: float):
super().__init__(
f"Sized storage volume ({storage_storageT_gal:.1f} gal) is less than the "
f"minimum required volume ({minimum_gal:.1f} gal). "
"Increase the hours the heat pump runs per day to ensure adequate volume."
)
self.storage_storageT_gal = storage_storageT_gal
self.capacity_kbtuh = capacity_kbtuh
def _load_shift_fract_total_vol(load_shift_percent: float) -> float:
"""
Convert a load-shift coverage percentile to a demand scaling fraction.
At load_shift_percent=1.0 the system is sized for 100% of days (no scaling).
Below 1.0, daily demand is assumed to follow a normal distribution and the
system is sized for the given percentile, accepting that higher-demand days
will occasionally breach the shed window.
Parameters
----------
load_shift_percent : float
Fraction of days the load-shift sizing must cover [0.25, 1.0].
Returns
-------
float
Scaling factor to apply to daily DHW demand during load-shift sizing (≤ 1.0).
"""
if load_shift_percent >= 1.0:
return 1.0
fract = _LS_NORM_DIST.inv_cdf(load_shift_percent)
return min(fract, 1.0)
# ---------------------------------------------------------------------------
# Module-level helpers
# ---------------------------------------------------------------------------
def _get_peak_indices(hourly_diff: np.ndarray) -> list[int]:
"""
Return the hours where the system transitions from surplus to deficit,
i.e. where hourly generation minus hourly demand goes from >= 0 to < 0.
These are the starting points for cumulative-deficit accumulation.
"""
n = len(hourly_diff)
return [
i for i in range(n)
if hourly_diff[i - 1] >= 0 and hourly_diff[i] < 0
]
# ---------------------------------------------------------------------------
# DHWSystem
# ---------------------------------------------------------------------------
[docs]
class DHWSystem:
"""
Base class for all domestic hot water system configurations.
Holds one or more WaterHeater objects, a StorageTank, and system-wide
temperature setpoints. Subclasses implement configuration-specific sizing
and simulation step logic.
Construction
------------
Do not call __init__ directly. Use one of the two factory class methods:
* DHWSystem.from_size(building, controls, ...)
Runs the sizing algorithm to find minimum required capacity and storage
volume, then builds one WaterHeater holding all that capacity. The
WaterHeater receives the provided Controls object; its on-sensor
parameters drive the stratification factor used during sizing.
* DHWSystem.from_components(storage_volume_storageT_gal, water_heaters, ...)
Builds the system from explicitly provided components.
"""
[docs]
def __init__(
self,
water_heaters: list[WaterHeater],
storage_tank: StorageTank | None,
supply_temp_f: float,
storage_temp_f: float,
max_daily_run_hr: float = 16.0,
defrost_factor: float = 1.0,
) -> None:
"""
Parameters
----------
water_heaters : list[WaterHeater]
One or more heater units in this system.
storage_tank : StorageTank | None
Primary storage tank. None only during intermediate construction.
supply_temp_f : float
DHW delivery temperature to building occupants [°F].
storage_temp_f : float
Hot water storage setpoint temperature [°F].
max_daily_run_hr : float
Maximum hours the heating system may run per day (1-24). Used to
calculate the required generation rate during sizing.
defrost_factor : float
Fraction of rated capacity available after accounting for defrost
cycles (0-1). Typically 1.0 for non-frosting conditions.
"""
self.water_heaters = water_heaters
self.storage_tank = storage_tank
self.supply_temp_f = supply_temp_f
self.storage_temp_f = storage_temp_f
self.max_daily_run_hr = max_daily_run_hr
self.defrost_factor = defrost_factor
# Sizing results — populated by size()
self._minimum_capacity_kbtuh: float | None = None
self._minimum_storage_storageT_gal: float | None = None
# ------------------------------------------------------------------
# Factory constructors
# ------------------------------------------------------------------
[docs]
@classmethod
def from_size(
cls,
building: Building,
supply_temp_f: float,
storage_temp_f: float,
max_daily_run_hr: float = 24.0,
defrost_factor: float = 1.0,
control_schedule: list[str] | None = None,
control_map: dict[str, Controls] | None = None,
strat_slope: float = 2.8,
load_shift_fract_total_vol: float = 1.0,
) -> DHWSystem:
"""
Size the system for the given building, then build it.
Runs the sizing algorithm to determine the minimum required heating
capacity and storage volume. Creates one WaterHeater backed by a
NominalPerformanceMap (constant-output placeholder) holding all of the
required capacity, and a StorageTank sized to the minimum required volume.
The control_map is used during sizing: each Controls in the map
contributes a stratification factor, and the minimum (worst-case) value
drives storage volume. The same schedule and map are assigned to the
created WaterHeater for use at simulation time.
Parameters
----------
building : Building
The building whose DHW load drives the sizing calculation.
Must have a ClimateZone (real or design-condition) so that design
inlet water temperature is available.
supply_temp_f : float
DHW delivery temperature [°F].
storage_temp_f : float
Hot water storage setpoint [°F].
max_daily_run_hr : float
Maximum hours the system may run per day. Lower values drive
higher capacity requirements and smaller storage requirements.
defrost_factor : float
Fraction of rated capacity available after defrost (0-1).
control_schedule : list[str] | None
24-element list mapping each hour of the day to a key in
control_map. Standard keys are ``"normal"``, ``"loadUp"``, and
``"shed"``. Assigned to the created WaterHeater. None when no
load-shifting or multi-mode control is required.
control_map : dict[str, Controls] | None
Maps control_schedule integers to Controls objects. All Controls
in the map are considered during sizing (worst-case strat factor).
None when no control logic is configured.
strat_slope : float
Temperature gradient through the tank's transition zone
[°F per percentage-point of tank height]. Stored on the
StorageTank and used during stratification factor calculations.
Subclasses that model different tank geometries should override
this via their own from_size() implementation.
Returns
-------
DHWSystem
"""
system = cls(
water_heaters=[],
storage_tank=None,
supply_temp_f=supply_temp_f,
storage_temp_f=storage_temp_f,
max_daily_run_hr=max_daily_run_hr,
defrost_factor=defrost_factor,
)
system.size(
building,
control_schedule=control_schedule,
control_map=control_map,
strat_slope=strat_slope,
load_shift_fract_total_vol=load_shift_fract_total_vol,
)
system.storage_tank = StratifiedTank(
total_volume_gal=system._minimum_storage_storageT_gal,
strat_slope=strat_slope,
)
system.water_heaters = [WaterHeater.from_nominal_capacity(
nominal_capacity_kbtuh=system._minimum_capacity_kbtuh,
control_schedule=control_schedule,
control_map=control_map,
)]
return system
[docs]
@classmethod
def from_components(
cls,
storage_volume_storageT_gal: float,
water_heaters: list[WaterHeater],
supply_temp_f: float,
storage_temp_f: float,
max_daily_run_hr: float = 24.0,
defrost_factor: float = 1.0,
strat_slope: float = 2.8,
) -> DHWSystem:
"""
Build the system from explicitly provided storage volume and heaters.
Use this path when storage volume and heating capacity are already
known (e.g. from a previous sizing run, from equipment specs, or
from user input) rather than being calculated from a building load.
Each WaterHeater in the list should already carry its own Controls
object.
Parameters
----------
storage_volume_storageT_gal : float
Physical tank volume at storage temperature [gallons].
water_heaters : list[WaterHeater]
Pre-built list of WaterHeater objects for this system. There is
no restriction on list length — one heater is the common case,
but staged systems may have more.
supply_temp_f : float
DHW delivery temperature [°F].
storage_temp_f : float
Hot water storage setpoint [°F].
max_daily_run_hr : float
Maximum hours the system may run per day.
defrost_factor : float
Fraction of rated capacity available after defrost (0-1).
strat_slope : float
Temperature gradient through the tank's transition zone
[°F per percentage-point of tank height]. Stored on the
StorageTank for use during simulation.
Returns
-------
DHWSystem
"""
return cls(
water_heaters=water_heaters,
storage_tank=StratifiedTank(
total_volume_gal=storage_volume_storageT_gal,
strat_slope=strat_slope,
),
supply_temp_f=supply_temp_f,
storage_temp_f=storage_temp_f,
max_daily_run_hr=max_daily_run_hr,
defrost_factor=defrost_factor,
)
# ------------------------------------------------------------------
# Sizing — public interface
# ------------------------------------------------------------------
[docs]
def size(
self,
building: Building,
control_schedule: list[str] | None = None,
control_map: dict[str, Controls] | None = None,
strat_slope: float = 2.8,
load_shift_fract_total_vol: float = 1.0,
) -> None:
"""
Compute the minimum heating capacity and storage volume for this
system in the given building. Stores results internally; retrieve
them with get_minimum_capacity_kbtuh() and
get_minimum_storage_storageT_gal().
Sizing is always performed on the 24-hour daily load shape. If the
building is currently set to the annual shape, this method
temporarily switches it back, sizes, then restores the annual shape.
If the control_map contains a ``"shed"`` key, load-shift sizing is
run in addition to normal sizing. The final capacity and storage volume
are the maximum of the two paths.
Parameters
----------
building : Building
control_schedule : list[str] | None
24-element schedule of control keys (``"normal"``, ``"loadUp"``,
``"shed"``). Required for load-shift sizing; ignored otherwise.
control_map : dict[str, Controls] | None
All Controls objects that may be active during operation. Each
Controls contributes a stratification factor; the minimum value
(worst case) drives storage volume sizing. Each Controls is also
checked for short-cycling risk. None uses sizing defaults.
strat_slope : float
Temperature gradient through the tank's transition zone
[°F per percentage-point of tank height]. Should match the
value that will be set on the StorageTank.
load_shift_fract_total_vol : float
Demand scaling factor for load-shift sizing (0–1). Derived from
load_shift_percent via _load_shift_fract_total_vol(). Default 1.0
(no scaling — size for 100% of days). Only applied to the LS sizing
path; normal sizing is always against the full daily demand.
Raises
------
ValueError
If the building has no design inlet water temperature available
(no ClimateZone was provided at construction).
"""
was_annual = building.is_annual_load_shape()
if was_annual:
building.set_to_daily_load_shape()
# When load shifting, the heater cannot run during shed hours, so the
# effective maximum daily run time is capped at the number of non-shed
# hours. Matches original: maxDayRun_hr = min(compRuntime_hr, sum(loadShiftSchedule)).
original_max_run_hr = self.max_daily_run_hr
if control_schedule and self._is_load_shifting(control_map):
non_shed_hours_hr = float(sum(1 for h in control_schedule if h != "shed"))
self.max_daily_run_hr = min(self.max_daily_run_hr, non_shed_hours_hr)
try:
design_inlet_temp_f = self._require_design_inlet_temp(building)
capacity_kbtuh = self._calc_required_capacity(building)
running_vol_supplyT_gal = self._calc_running_volume_supplyT_gal(building, capacity_kbtuh)
strat_factor = self._calc_stratification_factor(control_map, strat_slope, design_inlet_temp_f)
storage_vol_storageT_gal = self._calc_storage_volume_storageT_gal(
running_vol_supplyT_gal, strat_factor
)
if control_schedule and self._is_load_shifting(control_map):
ls_capacity_kbtuh = self._calc_required_capacity_ls_kbtuh(
control_schedule, control_map, building, strat_slope,
fract_total_vol=load_shift_fract_total_vol,
)
gen_rate_ls_gph = self._calc_gen_rate_ls_gph(
control_schedule, control_map, building, strat_slope,
fract_total_vol=load_shift_fract_total_vol,
)
ls_running_vol_supplyT_gal = self._calc_running_volume_ls_supplyT_gal(
control_schedule, building, gen_rate_ls_gph,
fract_total_vol=load_shift_fract_total_vol,
)
ls_storage_vol_storageT_gal = self._calc_storage_volume_ls_storageT_gal(
ls_running_vol_supplyT_gal, control_map, strat_slope, design_inlet_temp_f
)
capacity_kbtuh = max(capacity_kbtuh, ls_capacity_kbtuh)
storage_vol_storageT_gal = max(storage_vol_storageT_gal, ls_storage_vol_storageT_gal)
min_vol_gal = self._calc_minimum_running_volume_supplyT_gal(building)
if storage_vol_storageT_gal < min_vol_gal:
raise StorageVolumeTooSmallError(storage_vol_storageT_gal, min_vol_gal, capacity_kbtuh)
self._minimum_capacity_kbtuh = capacity_kbtuh
self._minimum_storage_storageT_gal = storage_vol_storageT_gal
self._sizing_strat_slope = strat_slope
if control_map:
self._warn_if_short_cycling(control_map, capacity_kbtuh, storage_vol_storageT_gal)
finally:
self.max_daily_run_hr = original_max_run_hr
if was_annual:
building.set_to_annual_load_shape()
[docs]
def get_minimum_capacity_kbtuh(self) -> float:
"""
Return the minimum required heating capacity [kBTU/hr] from sizing.
Raises
------
RuntimeError
If size() has not been called yet.
"""
if self._minimum_capacity_kbtuh is None:
raise RuntimeError("size() must be called before get_minimum_capacity_kbtuh().")
return self._minimum_capacity_kbtuh
[docs]
def get_minimum_storage_storageT_gal(self) -> float:
"""
Return the minimum required storage volume at storage temperature
[gallons] from sizing.
Raises
------
RuntimeError
If size() has not been called yet.
"""
if self._minimum_storage_storageT_gal is None:
raise RuntimeError("size() must be called before get_minimum_storage_storageT_gal().")
return self._minimum_storage_storageT_gal
[docs]
def get_sizing_curve(
self,
building: Building,
strat_slope: float = 2.8,
step: float = 0.25,
) -> dict:
"""
Compute the primary sizing curve — capacity vs. storage for varying run hours.
Sweeps ``max_daily_run_hr`` from 24 down to the physical minimum
(where the hourly generation rate equals peak hourly demand), sizing
without load-shift at each point. The resulting curve shows the
full capacity-vs-storage tradeoff available to the designer.
Because this calls the same internal sizing methods as ``size()``,
subclass overrides (e.g. ``RTPSystem`` adding recirc capacity) are
reflected automatically.
The sweep is split into two segments:
* ``[24, max_daily_run_hr)`` — the "over-designed" region to the left
of the recommended point.
* ``[max_daily_run_hr, min_run_hr)`` — the recommended point and
everything to the right.
``recommended_index`` is the length of the first segment, i.e. the
index in the returned lists that corresponds to ``max_daily_run_hr``.
Parameters
----------
building : Building
The building whose DHW load drives the sizing.
strat_slope : float
Temperature gradient [°F per %-height] for the stratification
factor calculation. Should match the value used for sizing.
Default 2.8.
step : float
Run-hour step size for the sweep. Default 0.25 hr.
Returns
-------
dict
``"heat_hours"`` : list[float] — run hrs at each point
``"capacity_kbtuh"`` : list[float] — capacity [kBTU/hr]
``"storage_storageT_gal"`` : list[float] — storage [gal at storageT]
``"recommended_index"`` : int — index of ``max_daily_run_hr``
"""
was_annual = building.is_annual_load_shape()
if was_annual:
building.set_to_daily_load_shape()
# Prefer the strat_slope that was actually used during size(), so the
# curve is self-consistent with sizing results.
_strat_slope = getattr(self, "_sizing_strat_slope", strat_slope)
try:
design_inlet = self._require_design_inlet_temp(building)
# Stratification factor is independent of run hours — compute once.
# Use the system's own control_map so the on-sensor fraction matches
# what size() uses. Falls back to None (conservative ~3.0 factor) if
# no water heaters have been attached yet.
_cmap = self.water_heaters[0].control_map if self.water_heaters else None
strat_factor = self._calc_stratification_factor(_cmap, _strat_slope, design_inlet)
# Physical minimum: one hour of generation equals the peak demand hour.
min_run_hr = 1.0 / float(np.max(building.peak_load_shape)) * 1.001
# Build sweep: [24 → max_daily_run_hr) ++ [max_daily_run_hr → min_run_hr)
arr1 = np.arange(24.0, self.max_daily_run_hr, -step)
arr2 = np.arange(self.max_daily_run_hr, min_run_hr, -step)
heat_hours = np.concatenate([arr1, arr2])
rec_index = len(arr1) # index of the recommended point
heat_hours_out: list[float] = []
capacity_out: list[float] = []
storage_out: list[float] = []
original_run_hr = self.max_daily_run_hr
try:
for h in heat_hours:
self.max_daily_run_hr = float(h)
try:
cap = self._calc_required_capacity(building)
running_vol = self._calc_running_volume_supplyT_gal(building, cap)
if running_vol == 0.0:
break # generation exceeds peak demand — physical minimum reached
storage_vol = self._calc_storage_volume_storageT_gal(
running_vol, strat_factor
)
except (ValueError, RuntimeError):
break # aquastat fraction or other sizing failure
if storage_vol < self._calc_minimum_running_volume_supplyT_gal(building):
break
else:
heat_hours_out.append(float(h))
capacity_out.append(cap)
storage_out.append(storage_vol)
finally:
self.max_daily_run_hr = original_run_hr
# If the sweep terminated before reaching the recommended point,
# clamp so rec_index always points at a valid entry.
rec_index = min(rec_index, max(0, len(heat_hours_out) - 1))
return {
"heat_hours": heat_hours_out,
"capacity_kbtuh": capacity_out,
"storage_storageT_gal": storage_out,
"recommended_index": rec_index,
}
finally:
if was_annual:
building.set_to_annual_load_shape()
[docs]
def get_ls_sizing_curve(
self,
building: Building,
control_schedule: list[str],
control_map: dict[str, Controls],
strat_slope: float = 2.8,
load_shift_percent: float = 1.0,
) -> dict:
"""
Compute the load-shift sizing curve — capacity and storage as a function
of demand-coverage percentile.
Sweeps ``load_shift_percent`` from 0.25 to 1.00 in 0.01 steps (76
points). At each step the demand fraction ``fract_total_vol`` is
derived from the normal-distribution model, and both normal and LS
sizing are run; the maximum of each is stored. This matches exactly
what ``size()`` does at a given ``load_shift_fract_total_vol``.
The x-axis of the resulting curve is the coverage percentile: at 1.00
the system is sized to handle the most demanding day (largest storage /
capacity); at 0.25 it accepts that 75 % of days will breach the shed
window (smallest system).
Parameters
----------
building : Building
control_schedule : list[str]
24-element schedule with ``"normal"``, ``"loadUp"``, ``"shed"``
keys.
control_map : dict[str, Controls]
Must include at least ``"normal"`` and ``"shed"`` entries.
strat_slope : float
Temperature gradient [°F per %-height] for stratification factor.
Default 2.8.
load_shift_percent : float
The system's configured coverage percentile (0.25–1.0). Used only
to locate ``recommended_index`` in the returned arrays.
Default 1.0.
Returns
-------
dict
``"load_shift_percent"`` : list[float] — 0.25 → 1.00
``"capacity_kbtuh"`` : list[float]
``"storage_storageT_gal"`` : list[float]
``"recommended_index"`` : int
Raises
------
ValueError
If ``control_map`` has no ``"shed"`` key (load-shift not configured).
"""
if not self._is_load_shifting(control_map):
raise ValueError(
"get_ls_sizing_curve() requires a control_map with a 'shed' key. "
"Use get_sizing_curve() for systems without load shifting."
)
was_annual = building.is_annual_load_shape()
if was_annual:
building.set_to_daily_load_shape()
# Prefer the strat_slope that was actually used during size().
_strat_slope = getattr(self, "_sizing_strat_slope", strat_slope)
# Mirror size(): cap max_daily_run_hr to non-shed hours so the normal
# pre-computation uses the same effective run time as size() does.
original_max_run_hr = self.max_daily_run_hr
non_shed_hours_hr = float(sum(1 for h in control_schedule if h != "shed"))
self.max_daily_run_hr = min(self.max_daily_run_hr, non_shed_hours_hr)
try:
design_inlet = self._require_design_inlet_temp(building)
# Pre-compute quantities that don't vary with fract_total_vol.
cap_normal = self._calc_required_capacity(building)
run_vol_normal = self._calc_running_volume_supplyT_gal(building, cap_normal)
strat_normal = self._calc_stratification_factor(
control_map, _strat_slope, design_inlet
)
stor_normal = self._calc_storage_volume_storageT_gal(
run_vol_normal, strat_normal
)
# Sweep load_shift_percent from 0.25 to 1.00 in integer percentile steps.
ls_percents: list[float] = [i / 100.0 for i in range(25, 101)]
capacity_out: list[float] = []
storage_out: list[float] = []
for ls_pct in ls_percents:
fract = _load_shift_fract_total_vol(ls_pct)
cap_ls = self._calc_required_capacity_ls_kbtuh(
control_schedule, control_map, building, _strat_slope, fract
)
gen_rate = self._calc_gen_rate_ls_gph(
control_schedule, control_map, building, _strat_slope, fract
)
run_vol_ls = self._calc_running_volume_ls_supplyT_gal(
control_schedule, building, gen_rate, fract
)
stor_ls = self._calc_storage_volume_ls_storageT_gal(
run_vol_ls, control_map, _strat_slope, design_inlet
)
capacity_out.append(max(cap_normal, cap_ls))
storage_out.append(max(stor_normal, stor_ls))
# Clamp load_shift_percent to the sweep range, then locate its index.
ls_pct_clamped = max(0.25, min(1.0, load_shift_percent))
rec_index = round((ls_pct_clamped - 0.25) * 100)
rec_index = max(0, min(rec_index, len(ls_percents) - 1))
return {
"load_shift_percent": ls_percents,
"capacity_kbtuh": capacity_out,
"storage_storageT_gal": storage_out,
"recommended_index": rec_index,
}
finally:
self.max_daily_run_hr = original_max_run_hr
if was_annual:
building.set_to_annual_load_shape()
[docs]
def plot_sizing_curve(
self,
building: Building,
control_schedule: list[str] | None = None,
control_map: dict[str, Controls] | None = None,
load_shift_percent: float = 1.0,
strat_slope: float = 2.8,
title: str = "Primary Sizing Curve",
filepath: str | None = None,
) -> "plotly.graph_objects.Figure":
"""
Return a Plotly figure of the primary sizing curve with an interactive
slider that moves a diamond marker along the curve.
**Normal sizing** (no load-shift):
* X-axis: primary tank volume [gal at storage temperature]
* Y-axis: heating capacity [kBTU/hr]
* Slider label: storage volume and run hours per day
**Load-shift sizing** (control_map contains a ``"shed"`` key):
* X-axis: load-shift coverage percentile [%]
* Y-axis: primary tank volume [gal at storage temperature]
* Slider label: % load-shift days covered and storage volume
In both cases the recommended point (at ``max_daily_run_hr`` or the
configured ``load_shift_percent``) is highlighted with a blue diamond
at page load.
Parameters
----------
building : Building
control_schedule : list[str] | None
Required for load-shift plots; ignored otherwise.
control_map : dict[str, Controls] | None
If it contains a ``"shed"`` key the load-shift curve is produced;
otherwise the normal sizing curve is used.
load_shift_percent : float
Configured load-shift coverage percentile (0.25–1.0). Only used
when producing the load-shift curve to position the recommended
marker. Default 1.0.
strat_slope : float
Temperature gradient [°F per %-height]. Default 2.8.
title : str
Figure title. Default ``"Primary Sizing Curve"``.
filepath : str | None
If provided, write the figure to this path as a self-contained
HTML file. The figure is also returned regardless.
Returns
-------
plotly.graph_objects.Figure
Raises
------
ImportError
If ``plotly`` is not installed.
"""
is_ls = self._is_load_shifting(control_map)
if is_ls:
curve = self.get_ls_sizing_curve(
building,
control_schedule=control_schedule,
control_map=control_map,
strat_slope=strat_slope,
load_shift_percent=load_shift_percent,
)
else:
curve = self.get_sizing_curve(building, strat_slope=strat_slope)
return self._build_sizing_curve_figure(curve, is_ls, title, filepath)
def _build_sizing_curve_figure(
self,
curve: dict,
is_ls: bool,
title: str = "Primary Sizing Curve",
filepath: str | None = None,
) -> "plotly.graph_objects.Figure":
"""
Build and return a Plotly figure from pre-computed sizing curve data.
Separating figure assembly from data computation lets callers reuse
the curve dict (e.g. to extract x/y points) without computing it twice.
Parameters
----------
curve : dict
Output of ``get_sizing_curve()`` or ``get_ls_sizing_curve()``.
is_ls : bool
True → load-shift curve layout; False → primary sizing curve layout.
title : str
Figure title.
filepath : str | None
If provided, write the figure to this path as a self-contained HTML file.
"""
try:
import plotly.graph_objects as go
except ImportError:
raise ImportError(
"plotly is required for plot_sizing_curve(). "
"Install it with: pip install plotly"
)
if is_ls:
x_vals = [p * 100.0 for p in curve["load_shift_percent"]]
y_vals = curve["storage_storageT_gal"]
rec = curve["recommended_index"]
x_label = "Load-Shift Days Covered (%)"
y_label = "Primary Tank Volume (gal at Storage Temperature)"
hover = (
"Load-shift coverage: <b>%{x:.0f}%</b><br>"
"Storage: <b>%{y:.1f} gal</b>"
"<extra></extra>"
)
def _slider_label(i: int) -> str:
return (
f"Coverage: <b>{x_vals[i]:.0f}%</b>, "
f"Storage: <b>{y_vals[i]:.1f} gal</b>"
)
else:
# Reverse raw curve (high heat-hours first) so slider moves
# left-to-right with increasing storage on the x-axis.
x_vals = curve["storage_storageT_gal"][::-1]
y_vals = curve["capacity_kbtuh"][::-1]
heat_hours = curve["heat_hours"][::-1]
rec = len(x_vals) - 1 - curve["recommended_index"]
x_label = "Primary Tank Volume (gal at Storage Temperature)"
y_label = "Heating Capacity (kBTU/hr)"
hover = (
"Storage: <b>%{x:.1f} gal</b><br>"
"Capacity: <b>%{y:.1f} kBTU/hr</b>"
"<extra></extra>"
)
def _slider_label(i: int) -> str:
return (
f"Storage: <b>{x_vals[i]:.1f} gal</b>, "
f"Capacity: <b>{y_vals[i]:.1f} kBTU/hr</b>, "
f"Run hours: <b>{heat_hours[i]:.2f} hr/day</b>"
)
fig = go.Figure()
# Trace 0: the full sizing curve (always visible)
fig.add_trace(go.Scatter(
x=x_vals, y=y_vals,
mode="lines",
line=dict(color="#28a745", width=3),
hovertemplate=hover,
showlegend=False,
))
# Traces 1…n: one diamond marker per slider step (hidden by default)
for i in range(len(x_vals)):
fig.add_trace(go.Scatter(
x=[x_vals[i]], y=[y_vals[i]],
mode="markers",
marker=dict(symbol="diamond", color="#2EA3F2", size=12),
hovertemplate=hover,
showlegend=False,
visible=(i == rec),
))
steps = []
for i in range(len(x_vals)):
visibility = [True] + [j == i for j in range(len(x_vals))]
steps.append(dict(
label=_slider_label(i),
method="update",
args=[{"visible": visibility}],
))
fig.update_layout(
title=title,
xaxis_title=x_label,
yaxis_title=y_label,
showlegend=False,
sliders=[dict(
steps=steps,
active=rec,
currentvalue=dict(
prefix="<b>Selected size</b>: ",
visible=True,
font=dict(size=14),
xanchor="left",
),
pad={"t": 60},
ticklen=0,
minorticklen=0,
bgcolor="#CCD9DB",
borderwidth=0,
)],
)
if filepath is not None:
fig.write_html(filepath)
return fig
# ------------------------------------------------------------------
# Sizing — internal helpers
# ------------------------------------------------------------------
def _calc_required_capacity(self, building: Building) -> float:
"""
Calculate total required heating capacity [kBTU/hr].
The system must deliver the entire daily DHW load within
max_daily_run_hr hours. The required generation rate (gallons per
hour) combined with the temperature rise and heat capacity of water
gives the minimum kBTU/hr needed.
Formula
-------
capacity = (daily_gal / max_daily_run_hr) * RHO_CP
* (supply_temp - design_inlet_temp) / defrost_factor / 1000
Parameters
----------
building : Building
Returns
-------
float
Required capacity [kBTU/hr].
"""
design_inlet_temp_f = self._require_design_inlet_temp(building)
gen_rate_gph = building.daily_dhw_use_supplyT_gal / self.max_daily_run_hr
delta_t = self.supply_temp_f - design_inlet_temp_f
return gen_rate_gph * _RHO_CP * delta_t / self.defrost_factor / 1000
def _calc_running_volume_supplyT_gal(
self,
building: Building,
capacity_kbtuh: float,
) -> float:
"""
Determine the running volume [gallons at supply temperature] — the
amount of hot storage the system must have available at the start of
the peak period to avoid running out during the design day.
The algorithm tiles the 24-hour load shape twice (to handle
midnight wrap-around), then finds the maximum cumulative deficit
starting from each hour where demand exceeds generation.
Parameters
----------
building : Building
capacity_kbtuh : float
Required capacity [kBTU/hr] (used by subclasses; the base class
derives generation rate directly from daily_gal / max_daily_run_hr).
Returns
-------
float
Running volume [gallons at supply temperature].
"""
daily_gal = building.daily_dhw_use_supplyT_gal
load_shape = building.peak_load_shape # 24 normalized fractions, sum = 1.0
# Hourly generation rate: system delivers the full daily demand
# within max_daily_run_hr hours, spread uniformly.
gen_rate_gph = daily_gal / self.max_daily_run_hr
hourly_demand_gph = daily_gal * load_shape # [gallons / hour] for each of 24 hours
hourly_diff_gph = gen_rate_gph - hourly_demand_gph # positive = surplus, negative = deficit
# Tile to two days so cumulative sums wrap around midnight correctly.
tiled_diff = np.tile(hourly_diff_gph, 2)
# Deficit accumulation starts at each transition from surplus to deficit.
peak_indices = _get_peak_indices(hourly_diff_gph)
if not peak_indices:
# Generation rate exceeds peak hourly demand — no storage required.
# This is the physical lower bound for max_daily_run_hr on the sizing curve.
return 0.0
running_vol = 0.0
for idx in peak_indices:
cum_diff = np.cumsum(tiled_diff[idx:])
neg_values = cum_diff[cum_diff < 0]
if len(neg_values) > 0:
running_vol = max(running_vol, float(-np.min(neg_values)))
return running_vol
def _calc_storage_volume_storageT_gal(
self,
running_volume_supplyT_gal: float,
stratification_factor: float,
) -> float:
"""
Convert running volume [gallons at supply temperature] to required
physical storage volume [gallons].
The stratification factor is the fraction of a 100-gallon physical
tank that can be delivered as supply-temperature water (accounting for
temperature mixing — hot water above supply mixes with cold inlet water
to produce more than its physical volume at supply temperature).
``tank_size = running_vol / stratification_factor``
Parameters
----------
running_volume_supplyT_gal : float
Cumulative deficit [gal at supply temperature].
stratification_factor : float
Supply-temperature gallons producible from a 100-gallon tank,
expressed as a fraction (0–1+), from
``_calc_supply_temp_gal_from_100gal_tank() / 100``.
Returns
-------
float
Required physical storage volume [gallons].
"""
return running_volume_supplyT_gal / stratification_factor
def _calc_minimum_running_volume_supplyT_gal(self, building) -> float:
"""Return the floor running volume: half the peak-hour demand at supply temperature."""
return float(np.max(building.peak_load_shape)) * building.daily_dhw_use_supplyT_gal / 2.0
def _calc_stratification_factor(
self,
control_map: dict[str, Controls] | None,
strat_slope: float,
inlet_temp_f: float,
) -> float:
"""
Calculate the stratification factor for the normal operating mode.
Returns ``_calc_supply_temp_gal_from_100gal_tank() / 100`` for the
"normal" Controls entry (or a fallback if no controls are provided).
This fraction directly drives storage volume sizing:
tank_size = running_vol / stratification_factor
When ``control_map`` is None or empty, sizing defaults to
``on_sensor_fract=0.0`` and ``on_trigger_t_f=supply_temp_f``.
Parameters
----------
control_map : dict[str, Controls] | None
strat_slope : float
Temperature gradient [°F per 1 % of tank height].
inlet_temp_f : float
Design cold-water inlet temperature [°F].
Returns
-------
float
Supply-temperature gallons from a 100-gallon tank, divided by 100.
"""
if not control_map:
return self._calc_supply_temp_gal_from_100gal_tank(
0.0, self.supply_temp_f, strat_slope, inlet_temp_f
) / 100.0
if "normal" in control_map:
ctrl = control_map["normal"]
return self._calc_supply_temp_gal_from_100gal_tank(
ctrl.on_sensor_fract, ctrl.on_trigger_t_f, strat_slope, inlet_temp_f
) / 100.0
# No "normal" key — use the worst-case (smallest factor) across all entries.
return min(
self._calc_supply_temp_gal_from_100gal_tank(
ctrl.on_sensor_fract, ctrl.on_trigger_t_f, strat_slope, inlet_temp_f
) / 100.0
for ctrl in control_map.values()
)
def _calc_supply_temp_gal_from_100gal_tank(
self,
on_fract: float,
on_temp_f: float,
strat_slope: float,
inlet_temp_f: float,
) -> float:
"""
Compute how many supply-temperature gallons a 100-gallon stratified
tank can produce, given that the ON sensor reads ``on_temp_f`` at
fractional height ``on_fract``.
Hot water above supply temperature is mixed with cold inlet water, so
1 physical gallon at temperature T produces:
(T − inlet_temp_f) / (supply_temp_f − inlet_temp_f)
supply-temperature gallons.
Temperature profile assumed:
- Below ``on_fract``: cold, not usable.
- At ``on_fract``: exactly ``on_temp_f``.
- Above ``on_fract``: rises linearly at ``strat_slope``
[°F per 1 % of tank height], capping at ``storage_temp_f``.
The integration runs from the height where T = ``supply_temp_f`` up
to the top of the tank (100 %). For a 100-gallon tank, 1 % = 1 gal.
Parameters
----------
on_fract : float
Fractional height of the ON sensor (0 = bottom, 1 = top).
on_temp_f : float
Tank temperature at the ON sensor when the element fires [°F].
strat_slope : float
Temperature gradient above the sensor [°F per 1 % of tank height].
inlet_temp_f : float
Design cold-water inlet temperature [°F].
Returns
-------
float
Supply-temperature gallons producible from a 100-gallon tank.
"""
on_pct = on_fract * 100.0
supply_delta = self.supply_temp_f - inlet_temp_f
# Heights (% of tank) where the linear gradient crosses supply / storage.
# T(h_pct) = on_temp + (h_pct − on_pct) × strat_slope for h_pct ≥ on_pct
supply_height_pct = on_pct + (self.supply_temp_f - on_temp_f) / strat_slope
storage_height_pct = min(
on_pct + (self.storage_temp_f - on_temp_f) / strat_slope,
100.0,
)
# If on_temp ≥ supply_temp, all water above the sensor is already hot;
# clamp so the full above-sensor zone is included.
supply_height_pct = max(supply_height_pct, on_pct)
if supply_height_pct >= 100.0:
return 0.0 # entire tank is below supply temperature
# Offsets from on_pct to the zone boundaries.
s1 = supply_height_pct - on_pct # ≥ 0; where T = supply_temp
s2 = storage_height_pct - on_pct # where T = storage_temp (or top)
# Transition zone [supply_height_pct → storage_height_pct]:
# T(u) = on_temp + u × strat_slope (u = h_pct − on_pct)
# supply-gal per physical gal = (T(u) − inlet) / supply_delta
# Integrate analytically (1 % height = 1 gallon in a 100-gal tank):
#
# ∫ₛ₁ˢ² (a + u·s) / supply_delta du where a = on_temp − inlet, s = strat_slope
# = [a·(s2−s1) + s·(s2²−s1²)/2] / supply_delta
a = on_temp_f - inlet_temp_f
transition_supply_gal = (
a * (s2 - s1) + strat_slope * (s2 ** 2 - s1 ** 2) / 2.0
) / supply_delta
# Fully-hot zone [storage_height_pct → 100 %]:
# All at storage_temp_f.
fully_hot_phys_gal = max(0.0, 100.0 - storage_height_pct)
fully_hot_supply_gal = fully_hot_phys_gal * (self.storage_temp_f - inlet_temp_f) / supply_delta
return transition_supply_gal + fully_hot_supply_gal
def _calc_avg_hot_temp_at_on_trigger(
self,
on_fract: float,
on_temp_f: float,
strat_slope: float,
) -> float:
"""
Compute the volume-weighted average temperature of all water at or
above ``supply_temp_f`` at the moment the ON sensor would trigger.
Uses the same linear profile as ``_calc_supply_temp_gal_from_100gal_tank``:
- Below ``on_fract``: cold, excluded.
- From ``on_fract`` upward: T(h_pct) = on_temp_f + (h_pct − on_pct) × strat_slope,
capped at ``storage_temp_f``.
The average is computed over physical gallons (not supply-temp-equivalent
gallons), so it reflects the actual mean temperature of the hot zone.
Returns ``supply_temp_f`` when there is no water above supply temperature
(i.e., the entire zone is at or below supply temp).
Parameters
----------
on_fract : float
Fractional height of the ON sensor (0 = bottom, 1 = top).
on_temp_f : float
Tank temperature at the ON sensor when the element fires [°F].
strat_slope : float
Temperature gradient above the sensor [°F per 1 % of tank height].
Returns
-------
float
Average temperature [°F] of all water at or above ``supply_temp_f``.
"""
on_pct = on_fract * 100.0
supply_height_pct = on_pct + (self.supply_temp_f - on_temp_f) / strat_slope
storage_height_pct = on_pct + (self.storage_temp_f - on_temp_f) / strat_slope
top_of_transition_temp_f = self.storage_temp_f
if storage_height_pct > 100.0:
top_of_transition_temp_f = on_temp_f + (100.0 - on_pct) * strat_slope
if supply_height_pct >= 100.0:
return self.supply_temp_f # no water above supply temperature
bottom_of_transition_temp_f = self.supply_temp_f
if supply_height_pct < 0:
bottom_of_transition_temp_f = on_temp_f - on_pct * strat_slope
# transitional average
transition_avg_temp_f = (top_of_transition_temp_f + bottom_of_transition_temp_f) / 2
transition_phys_gal = min(100.0, storage_height_pct) - max(0.0, supply_height_pct)
transition_temp_sum = transition_phys_gal * transition_avg_temp_f
# Fully-hot zone: all water above storage_height_pct is at storage_temp_f.
fully_hot_phys_gal = max(0.0, 100.0 - storage_height_pct)
fully_hot_temp_sum = self.storage_temp_f * fully_hot_phys_gal
total_phys_gal = transition_phys_gal + fully_hot_phys_gal
if total_phys_gal <= 0.0:
return self.supply_temp_f
return (transition_temp_sum + fully_hot_temp_sum) / total_phys_gal
def _strat_factor_for_on_params(
self,
on_fract: float,
on_temp_f: float,
strat_slope: float,
) -> float:
"""
Compute the stratification factor for a single (on_fract, on_temp_f) pair.
The tank temperature profile is modeled as a linear gradient in the
transition zone between cold and fully-hot layers. The slope of that
gradient is strat_slope [°F / %-height].
Parameters
----------
on_fract : float
Fractional height of the aquastat ON sensor (0 = bottom, 1 = top).
on_temp_f : float
Temperature at the aquastat sensor when the heater turns on [°F].
strat_slope : float
Temperature gradient [°F per percentage-point of tank height].
Returns
-------
float
Stratification factor (0-1). A value of 1.0 means all storage
above the aquastat is at full storage temperature (ideal).
"""
on_pct = on_fract * 100
delta_t = self.storage_temp_f - self.supply_temp_f
# Tank height (%) where temperature profile crosses supply and storage setpoints
supply_height_pct = on_pct + (self.supply_temp_f - on_temp_f) / strat_slope
storage_height_pct = on_pct + (self.storage_temp_f - on_temp_f) / strat_slope
storage_height_pct = min(storage_height_pct, 100.0)
# TODO : if storage_height_pct is 100, shouldn't we realculate
# delta_t based off of what temperature is actually at the top
# Clamp supply_height_pct so the transition zone stays within [on_pct, 100].
# If on_temp_f >= storage_temp_f the whole tank above the aquastat is fully
# hot, which gives a factor of 1.0 — the clamp produces that naturally.
supply_height_pct = max(supply_height_pct, on_pct)
# TODO: shouldn't supply_height_pct always just be where supply temp percentage height is on the tank?
# If there is some water that is supply temp under on_pct, it is still usable water
# Volume above supply temp = fully-hot zone + trapezoidal transition zone
vol_fully_hot = (100 - storage_height_pct) * delta_t
vol_transition = (storage_height_pct - supply_height_pct) * delta_t / 2
# TODO : delta T in the above two lines should, I am pretty sure, be the difference between supply temp (or lowest emp in tank if whole tank is above supply)
# and true top of tank temperature
vol_above_supply = vol_fully_hot + vol_transition
# Ideal case: all volume above the aquastat is at full storage temp
ideal_vol = (100 - on_pct) * delta_t
# TODO : delta_t in this case is actually the difference between storage and supply as this is a perfectly stratified tank
return vol_above_supply / ideal_vol
def _strat_pct_of_tank(
self,
on_fract: float,
on_temp_f: float,
strat_slope: float,
) -> float:
"""
Return the fraction of the *total* tank volume that is at or above
supply temperature when the ON sensor is at on_fract and reads
on_temp_f.
This is the "percent of whole tank" form of the stratification factor:
strat_pct = strat_factor * (1 - on_fract)
Used in load-shift sizing where the effective storage band is the
difference between two aquastat levels expressed as fractions of the
entire tank volume, not just the volume above one aquastat.
Parameters
----------
on_fract : float
on_temp_f : float
strat_slope : float
Returns
-------
float
"""
return self._strat_factor_for_on_params(on_fract, on_temp_f, strat_slope) * (1.0 - on_fract)
@staticmethod
def _is_load_shifting(control_map: dict[str, Controls] | None) -> bool:
"""Return True if the control_map has a ``"shed"`` key."""
return bool(control_map) and "shed" in control_map
@staticmethod
def _get_first_shed_block_and_load_up_hours(
control_schedule: list[str],
) -> tuple[list[int], int]:
"""
Find the first consecutive block of ``"shed"`` hours in the schedule
and count the ``"loadUp"`` hours immediately preceding it.
Parameters
----------
control_schedule : list[str]
24-element list of control keys.
Returns
-------
first_shed_block : list[int]
Hour indices (0-23) of the first consecutive ``"shed"`` run.
load_up_hours : int
Number of consecutive ``"loadUp"`` hours directly before the
first shed block. 0 if no load-up hours are configured.
"""
shed_indices = [h for h in range(24) if control_schedule[h] == "shed"]
if not shed_indices:
return [], 0
# Build first consecutive shed block
first_shed_block = [shed_indices[0]]
for h in shed_indices[1:]:
if h == first_shed_block[-1] + 1:
first_shed_block.append(h)
else:
break
# Count consecutive "loadUp" hours immediately before the first shed
load_up_hours = 0
h = first_shed_block[0] - 1
while h >= 0 and control_schedule[h] == "loadUp":
load_up_hours += 1
h -= 1
return first_shed_block, load_up_hours
def _calc_prelim_vols_supplyT_gal(
self,
control_schedule: list[str],
building: Building,
fract_total_vol: float = 1.0,
) -> tuple[float, float]:
"""
Calculate volumes consumed during the first shed block and the
preceding load-up period.
Parameters
----------
control_schedule : list[str]
building : Building
fract_total_vol : float
Demand scaling factor from load_shift_percent. Applied to vshift
(the volume needed to carry through the first shed) to match the
original's _calcPrelimVol behavior. Default 1.0 (no scaling).
Returns
-------
vshift_supplyT_gal : float
Volume [gal at supplyT] consumed during the first shed block,
scaled by fract_total_vol.
vconsumed_lu_supplyT_gal : float
Volume [gal at supplyT] consumed during the load-up hours.
The heater must both fill Vload AND offset this demand.
"""
first_shed_block, load_up_hours = self._get_first_shed_block_and_load_up_hours(control_schedule)
load_shape_gph = building.avg_load_shape * building.daily_dhw_use_supplyT_gal
vshift_supplyT_gal = float(sum(load_shape_gph[h] for h in first_shed_block)) * fract_total_vol
lu_start = first_shed_block[0] - load_up_hours
vconsumed_lu_supplyT_gal = float(sum(load_shape_gph[h] for h in range(lu_start, first_shed_block[0])))
return vshift_supplyT_gal, vconsumed_lu_supplyT_gal
def _calc_gen_rate_ls_gph(
self,
control_schedule: list[str],
control_map: dict[str, Controls],
building: Building,
strat_slope: float,
fract_total_vol: float = 1.0,
) -> float:
"""
Calculate the load-shift generation rate [gal/hr at supplyT].
The LS generation rate is the maximum of:
* Normal gen rate: ``daily_gal / max_daily_run_hr``
* Load-up gen rate: rate needed to fill the load-up portion of the
tank AND offset demand during the load-up hours.
When no ``"loadUp"`` key is in the map or ``load_up_hours == 0``,
returns the normal gen rate.
Parameters
----------
control_schedule : list[str]
control_map : dict[str, Controls]
building : Building
strat_slope : float
fract_total_vol : float
Demand scaling factor from load_shift_percent. Passed through to
_calc_prelim_vols_supplyT_gal. Default 1.0 (no scaling).
Returns
-------
float
Generation rate [gal/hr at supplyT].
"""
daily_gal = building.daily_dhw_use_supplyT_gal
normal_gen_rate_gph = daily_gal / self.max_daily_run_hr #TODO min of this and number of non-shed hours?
_, load_up_hours = self._get_first_shed_block_and_load_up_hours(control_schedule)
if load_up_hours == 0:
return normal_gen_rate_gph
vshift_supplyT_gal, vconsumed_lu_supplyT_gal = self._calc_prelim_vols_supplyT_gal(
control_schedule, building, fract_total_vol
)
normal_ctrl = control_map["normal"]
lu_ctrl = control_map.get("loadUp", normal_ctrl)
shed_ctrl = control_map["shed"]
normal_strat_pct = self._strat_pct_of_tank(
normal_ctrl.on_sensor_fract, normal_ctrl.on_trigger_t_f, strat_slope
)
lu_strat_pct = self._strat_pct_of_tank(
lu_ctrl.on_sensor_fract, lu_ctrl.on_trigger_t_f, strat_slope
)
shed_strat_pct = self._strat_pct_of_tank(
shed_ctrl.on_sensor_fract, shed_ctrl.on_trigger_t_f, strat_slope
)
ls_band = lu_strat_pct - shed_strat_pct
if ls_band <= 0:
return normal_gen_rate_gph
# Volume in the load-up zone (between normal and load-up aquastats)
vload_supplyT_gal = vshift_supplyT_gal * (lu_strat_pct - normal_strat_pct) / ls_band
lu_gen_rate_gph = (vload_supplyT_gal + vconsumed_lu_supplyT_gal) / load_up_hours
return max(normal_gen_rate_gph, lu_gen_rate_gph)
def _calc_required_capacity_ls_kbtuh(
self,
control_schedule: list[str],
control_map: dict[str, Controls],
building: Building,
strat_slope: float,
fract_total_vol: float = 1.0,
) -> float:
"""
Calculate required heating capacity [kBTU/hr] for load-shift sizing.
Converts the load-shift generation rate (max of normal and load-up
rates) to a heating capacity via the standard formula.
Parameters
----------
control_schedule : list[str]
control_map : dict[str, Controls]
building : Building
strat_slope : float
fract_total_vol : float
Demand scaling factor from load_shift_percent. Passed through to
_calc_gen_rate_ls_gph. Default 1.0 (no scaling).
Returns
-------
float
Required heating capacity [kBTU/hr].
"""
design_inlet_temp_f = self._require_design_inlet_temp(building)
gen_rate_ls_gph = self._calc_gen_rate_ls_gph(
control_schedule, control_map, building, strat_slope, fract_total_vol
)
delta_t = self.supply_temp_f - design_inlet_temp_f
return gen_rate_ls_gph * _RHO_CP * delta_t / self.defrost_factor / 1000
def _calc_running_volume_ls_supplyT_gal(
self,
control_schedule: list[str],
building: Building,
gen_rate_ls_gph: float,
fract_total_vol: float = 1.0,
) -> float:
"""
Calculate the load-shift running volume [gal at supplyT].
The tank is modeled as "empty" (only Vshift above the shed aquastat)
at the moment the first shed ends. From that point forward the
cumulative deficit between generation and demand gives the additional
volume needed above Vshift.
Parameters
----------
control_schedule : list[str]
building : Building
gen_rate_ls_gph : float
Load-shift generation rate [gal/hr at supplyT], from
_calc_gen_rate_ls_gph.
fract_total_vol : float
Demand scaling factor from load_shift_percent (0–1). Scales the
daily demand profile so the system is sized for the given percentile
of days rather than the absolute peak. Default 1.0 (no scaling).
Returns
-------
float
Load-shift running volume [gal at supplyT].
"""
first_shed_block, _ = self._get_first_shed_block_and_load_up_hours(control_schedule)
vshift_supplyT_gal, _ = self._calc_prelim_vols_supplyT_gal(
control_schedule, building, fract_total_vol
)
load_shape = building.avg_load_shape
daily_gal = building.daily_dhw_use_supplyT_gal
# 24-hr generation profile: gen_rate_ls during non-shed hours, 0 during shed
gen_profile_gph = np.array([
0.0 if control_schedule[h] == "shed" else gen_rate_ls_gph
for h in range(24)
])
demand_profile_gph = daily_gal * load_shape
diff_gph = gen_profile_gph - demand_profile_gph
# Accumulate deficit starting from the first hour after the shed ends.
# The tank is "empty" at that point — it holds only Vshift above shedT.
shed_end_idx = first_shed_block[-1] + 1
tiled_diff = np.tile(diff_gph, 2)
cum_diff = np.cumsum(tiled_diff[shed_end_idx:])
neg_values = cum_diff[cum_diff < 0]
ls_deficit_supplyT_gal = float(-np.min(neg_values)) if len(neg_values) > 0 else 0.0
# Post-multiply the deficit by fract_total_vol to match the original's behavior:
# the sizing is against unscaled demand but the deficit is scaled back down.
ls_deficit_supplyT_gal *= fract_total_vol
return ls_deficit_supplyT_gal + vshift_supplyT_gal
def _calc_storage_volume_ls_storageT_gal(
self,
ls_running_vol_supplyT_gal: float,
control_map: dict[str, Controls],
strat_slope: float,
inlet_temp_f: float,
) -> float:
"""
Convert the load-shift running volume [gal at supplyT] to required
physical storage [gallons].
The effective stratification denominator for load-shift sizing is the
difference in supply-temperature capacity between the load-up and shed
aquastat positions (both expressed as fractions of a 100-gallon tank).
Parameters
----------
ls_running_vol_supplyT_gal : float
control_map : dict[str, Controls]
strat_slope : float
inlet_temp_f : float
Design cold-water inlet temperature [°F].
Returns
-------
float
Required physical storage volume [gallons].
"""
normal_ctrl = control_map["normal"]
lu_ctrl = control_map.get("loadUp", normal_ctrl)
shed_ctrl = control_map["shed"]
# lu_x = self._calc_supply_temp_gal_from_100gal_tank(
# lu_ctrl.on_sensor_fract, lu_ctrl.on_trigger_t_f, strat_slope, inlet_temp_f
# )
lu_x = self._calc_supply_temp_gal_from_100gal_tank(
lu_ctrl.off_sensor_fract, lu_ctrl.off_trigger_t_f, strat_slope, inlet_temp_f
)
shed_x = self._calc_supply_temp_gal_from_100gal_tank(
shed_ctrl.on_sensor_fract, shed_ctrl.on_trigger_t_f, strat_slope, inlet_temp_f
)
ls_band = (lu_x - shed_x) / 100.0
return self._calc_storage_volume_storageT_gal(
ls_running_vol_supplyT_gal, ls_band
)
def _require_design_inlet_temp(self, building: Building) -> float:
"""
Return the design inlet water temperature, raising a clear error if
it is unavailable (i.e. no ClimateZone was set on the building).
"""
temp = building.get_design_inlet_water_temp_f()
if temp is None:
raise ValueError(
"Sizing requires a design inlet water temperature. "
"Provide a ClimateZone (via zip code, weather station, zone ID, "
"or design_inlet_water_temp_f) when constructing the Building."
)
return temp
# Minimum heater cycle time below which short cycling is flagged [minutes].
_MIN_CYCLE_MIN: float = 10.0
def _warn_if_short_cycling(
self,
control_map: dict[str, Controls],
capacity_kbtuh: float,
storage_vol_storageT_gal: float,
) -> None:
"""
Emit a UserWarning for any Controls in the map that would cause short
cycling or have backwards sensor positions.
Each Controls in control_map is checked independently. Short cycling
occurs when the deadband volume (between ON and OFF sensors) is small
relative to the heater's output rate.
Estimated cycle time per Controls:
deadband_vol = (on_fract - off_fract) * storage_vol
heat_rate_gph = capacity_kbtuh * 1000 / (RHO_CP * (storage_T - supply_T))
cycle_time = deadband_vol / heat_rate_gph [hours]
Parameters
----------
control_map : dict[str, Controls]
capacity_kbtuh : float
Minimum required heating capacity [kBTU/hr] from sizing.
storage_vol_storageT_gal : float
Minimum required storage volume [gallons] from sizing.
"""
delta_t_storage = self.storage_temp_f - self.supply_temp_f
if delta_t_storage <= 0:
return # degenerate temperatures — skip check
heat_rate_gph = capacity_kbtuh * 1000 / (_RHO_CP * delta_t_storage)
for key, ctrl in control_map.items():
if ctrl.off_sensor_fract > ctrl.on_sensor_fract:
warnings.warn(
f"Controls key {key}: off_sensor_fract ({ctrl.off_sensor_fract}) "
f"is above on_sensor_fract ({ctrl.on_sensor_fract}). "
f"Expected off <= on — the heater may never shut off.",
UserWarning,
stacklevel=4,
)
continue
deadband_vol_gal = (ctrl.on_sensor_fract - ctrl.off_sensor_fract) * storage_vol_storageT_gal
cycle_time_min = (deadband_vol_gal / heat_rate_gph) * 60
if cycle_time_min < self._MIN_CYCLE_MIN:
warnings.warn(
f"Controls key {key}: short cycling risk — estimated cycle time is "
f"{cycle_time_min:.1f} min (minimum recommended: {self._MIN_CYCLE_MIN} min). "
f"Consider increasing storage volume or widening the sensor deadband "
f"(on_sensor_fract={ctrl.on_sensor_fract}, off_sensor_fract={ctrl.off_sensor_fract}).",
UserWarning,
stacklevel=4,
)
# ------------------------------------------------------------------
# Simulation step (stubs — implemented in subclasses)
# ------------------------------------------------------------------
[docs]
def simulate_step(
self,
building: Building,
timestep_interval: int,
interval_min: int = 1,
mode: str = "normal",
) -> dict:
"""
Execute one simulation timestep: query controls, apply heating,
draw DHW from tank. Returns per-step metrics.
Order of operations
-------------------
1. Query Building for demand, OAT, and inlet water temperature.
2. Determine outlet_temp_f for the current hour from active Controls.
3. Update each WaterHeater's on/off state via its Controls.
4. Sum heating output from all active heaters; apply to storage tank.
5. Draw DHW from tank to meet demand.
6. Return per-step metrics dict.
Parameters
----------
building : Building
timestep_interval : int
Current simulation interval index from the start of the simulation.
interval_min : int
Length of each interval in minutes.
mode : str
Ignored — operating mode is determined automatically by each
WaterHeater's control_schedule for the current hour.
Returns
-------
dict
Keys: 'demand_supplyT_gal', 'usable_volume_supplyT_gal',
'heater_output_kbtuh', 'heater_power_in_kw', 'oat_f',
'inlet_water_temp_f', 'tank_temps_f'.
"""
use_avg = any(wh.is_load_shifting() for wh in self.water_heaters)
demand_supplyT_gal = building.get_dhw_load_supplyT_gal(
timestep_interval, interval_min, use_avg=use_avg
)
# NOTE: The original EcosizerEngine scaled hwDemand by fract_total_vol
# (derived from load_shift_percent) in the simulation as well as sizing.
# This codebase intentionally does NOT do that. Sizing is scaled so the
# system is optimally sized for the target percentile of days, but the
# simulation always runs against the full unscaled average daily demand.
# The practical consequence: a system sized with load_shift_percent < 1.0
# may show the primary heater firing during shed on some simulated days,
# which is the expected and honest behavior for a design that accepts
# occasional shed violations in exchange for a smaller tank.
oat_f = building.get_oat_f(timestep_interval, interval_min)
inlet_temp_f = building.get_inlet_water_temp_f(timestep_interval, interval_min)
hour_of_day = (timestep_interval * interval_min // 60) % 24
outlet_temp_f = self._get_outlet_temp_f(hour_of_day)
mode = (
self.water_heaters[0].control_schedule[hour_of_day]
if self.water_heaters and self.water_heaters[0].control_schedule
else "normal"
)
if self.storage_tank is not None:
# Update on/off state for each heater based on current tank condition
for wh in self.water_heaters:
wh.update_state(self.storage_tank, hour_of_day)
# Apply heating from all active heaters to the tank
total_kbtuh = sum(
wh.get_output_kbtuh(oat_f, wh.get_outlet_temp_f(hour_of_day), inlet_temp_f)
for wh in self.water_heaters
)
total_kw: float | None = None
active_kws = [
wh.get_power_in_kw(oat_f, wh.get_outlet_temp_f(hour_of_day), inlet_temp_f)
for wh in self.water_heaters
if wh.is_active()
]
if any(kw is not None for kw in active_kws):
total_kw = sum(kw or 0.0 for kw in active_kws)
self.storage_tank.heat(total_kbtuh, interval_min, outlet_temp_f)
top_temp_f = self.storage_tank.get_temperature_at_fraction(1.0)
# Draw hot water from tank to meet demand
if top_temp_f >= self.supply_temp_f:
self.storage_tank.draw(
demand_supplyT_gal, inlet_temp_f, self.supply_temp_f, outlet_temp_f
)
else:
self.storage_tank.draw_physical_gal(demand_supplyT_gal, inlet_temp_f, self.supply_temp_f)
usable_vol_gal = self.storage_tank.get_usable_volume_supplyT_gal(
self.supply_temp_f
)
tank_temps_f = [
self.storage_tank.get_temperature_at_fraction(f)
for f in (0.0, 0.2, 0.4, 0.6, 0.8, 1.0)
]
else:
total_kbtuh = 0.0
total_kw = None
usable_vol_gal = 0.0
tank_temps_f = [0.0] * 6
return {
"demand_supplyT_gal": demand_supplyT_gal,
"usable_volume_supplyT_gal": usable_vol_gal,
"heater_output_kbtuh": total_kbtuh,
"heater_power_in_kw": total_kw,
"oat_f": oat_f,
"inlet_water_temp_f": inlet_temp_f,
"tank_temps_f": tank_temps_f,
"mode": mode,
}
def _get_outlet_temp_f(self, hour_of_day: int) -> float:
"""
Return the maximum outlet temperature among all water heaters' active
Controls for the given hour. Falls back to storage_temp_f if no
Controls are configured.
Parameters
----------
hour_of_day : int
Hour of the day (0-23).
Returns
-------
float
"""
outlet_temps = [
wh.get_controls_for_hour(hour_of_day).outlet_temp_f
for wh in self.water_heaters
if wh.get_controls_for_hour(hour_of_day) is not None
]
return max(outlet_temps) if outlet_temps else self.storage_temp_f
[docs]
def check_for_outage(self, demand_supplyT_gal: float) -> bool:
"""
Return True if the storage tank cannot meet the given demand.
Checks whether usable volume at supply temperature has reached zero.
Parameters
----------
demand_supplyT_gal : float
Hot water demand at supply temperature [gallons].
Returns
-------
bool
"""
if self.storage_tank is None:
return False
return self.storage_tank.get_usable_volume_supplyT_gal(self.supply_temp_f) <= 0.0